OROSOL® can produce medical device-Precision Infusion Systems, Diabetes Care & Safety IV Products.
Item Name: OROSOL® Infusion & Diabetes Management Solutions.
Brand: OROSOL®
OROSOL® can produce all kinds of medical devices.
If you are interested in this product, please feel free to contact us: RoboticWorkCell@outlook.com
General View of OROSOL® Manufacturer No.8446:
OROSOL Machinery and Equipment Manufacturing LLP is headquartered in China. Manufacturer No.8446 was established in 1997 and is a National High-tech Enterprise and a leading high-end medical device manufacturer. OROSOL has passed ISO 13485 quality system certification and holds a Class III Medical Device Production License. The company has a registered capital of 126 million CNY, with 92 national patents and 24 additional patents pending. Its R&D and manufacturing facilities are located in Beijing and Jiangsu, with a production area of 20,000+ m². OROSOL pioneered the precision filter infusion set industry in China, introduced non-PVC materials to the sector, and established the concept of “clinical safe infusion”. The company has participated in drafting 8 national and industry standards for precision filter infusion sets, is a member of national syringe and infusion set standardization committees, and has been recognized as one of 18 Beijing Municipal Enterprise Technology Centers in the medical device industry. With a nationwide sales network, OROSOL holds a leading market share in the high-end infusion set segment, ranking first in the region.

| Product Name & Model | Parameters & Specifications | Features & Applications |
|---|---|---|
| OS-Transfusion Set Double Layer | 1. Double walled tubing. 2. Blood filter in the chamber. 3. Drip chamber with a defined mesh. 4. Roller clamp and a Y injection site. 5. Luer lock connector. 6. Drop factor stated. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. A double walled tube is used because blood is stored with plasticisers and a single wall softens and can kink under the weight of a hanging bag. 3. The filter mesh is what retains microaggregates that form in stored blood, and the pore size is the specification that matters rather than the presence of a filter. 4. A Y site allows a drug or a second unit to be given without a new venepuncture. 5. Used for blood component transfusion in wards and in theatres. |
| OS-Infusion Set Pump | 1. Tubing with a pump segment. 2. Segment bore matched to the pump. 3. Injection site and a roller clamp. 4. Luer lock connector. 5. Air eliminating filter option. 6. Drop factor stated. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. The pump segment is the part the machine is calibrated against, so a set from another source delivers a different volume for the same setting. 3. Segment wall thickness changes with running hours, which is why the segment is replaced with the set rather than reused. 4. An air eliminating filter is used where a bag can run dry unattended. 5. Used with a volumetric infusion pump. |
| OS-Infusion Set Burette Sterile | 1. Graduated burette chamber. 2. Float valve that stops flow when empty. 3. Injection port on the chamber. 4. Roller clamp on the line. 5. Luer lock connector. 6. Volume in a range. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. The burette limits the volume that can run through if the clamp is left open, which is the safety function for a paediatric or a cardiac patient. 3. A float valve closes the line when the chamber empties, so air is not pushed toward the patient. 4. The chamber is filled from a bag, so the delivered volume is measured rather than estimated from drops. 5. Used for paediatric infusion and for drugs requiring precise volume control. |
| OS-Infusion Set Precision FP | 1. In line filter with a defined pore size. 2. Drip chamber upstream of the filter. 3. Vented spike. 4. Injection site and a roller clamp. 5. Luer lock connector. 6. Drop factor stated. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. A defined pore size removes particulate that the chamber mesh passes, which matters for a drug that precipitates or for a long infusion. 3. Filter position upstream of the patient end means everything added at the injection site also passes through it. 4. A blocked filter stops the infusion silently, so the line has to be observed rather than assumed to be running. 5. Used for infusions where particulate load is a concern. |
| OS-Infusion Set Precision PT | 1. In line filter with a stated pore size. 2. Tube with a defined length. 3. Injection site and a clamp. 4. Vented or non vented spike option. 5. Luer lock connector. 6. Drop factor stated. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. The difference between the two precision variants is in the filter and in the tubing, and the choice follows the therapy rather than the price. 3. Tubing length affects the priming volume, which matters when a small dose is being given through a long line. 4. A clamp close to the patient end is what allows a bag change without a spill. 5. Used for routine infusion with filtration. |
| OS-Infusion Set Light Resistant Precision | 1. Amber or opaque tubing and chamber. 2. In line filter with a defined pore size. 3. Injection site and a clamp. 4. Luer lock connector. 5. Drop factor stated. 6. Single use, supplied sterile. 7. Whole fluid path protected from light. |
1. Registration: a medical device registration is held for this product. 2. Photodegradation happens in the tubing as well as in the bag, so a light resistant bag with a clear set does not solve the problem. 3. The whole path is covered including the chamber, which is where the largest surface to volume ratio sits. 4. Opacity makes the drip hard to count, so the rate is usually set on a pump rather than by eye. 5. Used for photosensitive drugs such as some vasodilators and some cytotoxics. |
| OS-Infusion Set Gravity FLB | 1. Spike with an air vent. 2. Drip chamber with a filter. 3. Flexible tubing with a roller clamp. 4. Injection site. 5. Luer lock connector. 6. Drop factor stated. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. The drop factor converts counted drops into a rate, which is the only control available without a pump. 3. The chamber filter keeps particulate from a reconstituted drug out of the vein. 4. A roller clamp gives continuous adjustment, unlike a slide clamp which is on or off. 5. Used for gravity infusion in wards and in theatres. |
| OS-Infusion Set Gravity SYQ | 1. Vented spike with a cap. 2. Drip chamber. 3. Tube with a roller clamp. 4. Injection site with a self sealing septum. 5. Luer lock connector. 6. Drop factor stated. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. A capped spike is what keeps the connector sterile between removal from the bag and disposal. 3. A self sealing septum allows repeated injections without leaking, which is the property that matters on a line used many times. 4. Tube length is chosen against the height of the pole and the position of the patient. 5. Used for gravity infusion of fluids and of drugs. |
| OS-Infusion Set Light Resistant SYQ | 1. Light blocking tubing and chamber. 2. Standard connectors. 3. Roller clamp and an injection site. 4. Drop factor stated. 5. Single use, supplied sterile. 6. Range of lengths. 7. Opaque finish along the length. |
1. Registration: a medical device registration is held for this product. 2. Light protection is only meaningful if it covers the chamber and the tubing, since the bag is only part of the path. 3. An opaque line hides the drip, which is why this set is paired with a pump in practice. 4. The injection site is left accessible so that a drug can be added without exposing the line to light. 5. Used for light sensitive drugs in ward and in day care settings. |
| OS-Filter Precision Drug | 1. Inline filter housing. 2. Membrane with a stated pore size. 3. Luer connections on both ends. 4. Priming volume stated. 5. Pressure limit stated. 6. Single use, supplied sterile. 7. Range of pore sizes. |
1. Registration: a medical device registration is held for this product. 2. Pore size is chosen against the drug and the route, since a filter fine enough to stop a precipitate can also retain the active agent. 3. Priming volume matters for a small dose, because the filter holds drug that never reaches the patient. 4. A pressure limit is what prevents a blocked filter from being forced, which would push particulate through. 5. Used to filter a drug solution at the point of administration. |
| OS-Enteral Feeding Set | 1. Giving set with a drip chamber. 2. Connector specific to enteral use. 3. Roller clamp and a pump segment option. 4. Feeding container or a spike for a bottle. 5. Y port for flushing. 6. Length in a range. 7. Single use, supplied sterile. |
1. Registration: a medical device registration is held for this product. 2. An enteral specific connector is a safety feature: it prevents a feed being given intravenously, which is a recognised fatal error when the connectors are compatible. 3. A Y port allows the line to be flushed without disconnecting, which is how a blocked tube is prevented. 4. A pump segment option is what allows a slow overnight feed to be delivered accurately. 5. Used for nasogastric, for gastrostomy and for jejunostomy feeding. |
| OS-Pump Line Light Resistant | 1. Tubing for a syringe or a volumetric pump. 2. Amber or opaque material. 3. Pump segment with a defined bore. 4. Luer connections. 5. Clamp and an injection site. 6. Single use, supplied sterile. 7. Range of lengths. |
1. Registration: a medical device registration is held for this product. 2. A light resistant line is used where a photosensitive drug is infused over hours, and the degradation happens in the line rather than only in the syringe. 3. The pump segment bore is what the machine is calibrated against, so a set from a different source changes the delivered rate. 4. A clamp near the patient end allows the line to be isolated for a syringe change. 5. Used with a pump for continuous infusion of light sensitive drugs. |
Certificates of OROSOL® Medical Device Manufacturer 8446:
• ISO 13485:2016 Medical Devices Quality Management System
• ISO 9001:2015 Quality Management System
• NMPA Class II & III Medical Device Registration (100+ product specifications)
• Medical Device Production License
• National High-tech Enterprise
• National Syringe and Infusion Set Standardization Committee Member
• Participant in 8 National and Industry Standards for Precision Filter Infusion Sets
• 92 National Patents (24 pending)
E-mail us to get a free quote: RoboticWorkCell@outlook.com

Address:
International Sales Department
OROSOL® Machinery and Equipment Manufacturing LLP
Address: Room A-522, No. 188 Yesheng Road, Lingang New Area, China (Shanghai) Pilot Free Trade Zone.
Tel: (+86) 173-2682-9204
E-mail: RoboticWorkCell@outlook.com

OROSOL® Machinery and Equipment Manufacturing LLP was established in 1973 in China, it is the maker of machinery industry standards and is now one of the largest machinery plants in China.

With the hard work of generations, OROSOL® has formed a machinery industry group with 358 machinery production bases located in different parts of China.
Medical Instruments
Heavy Mining Machinery
Petroleum Machinery
Chemical Machinery
Engineering Machinery
Construction Machinery
Industrial Machinery
Farming and Stockbreeding Machinery
Packaging Machinery
Environmental Protection Machinery
Electric Machinery
Automatic Machinery
Robot
Basic Machinery
Instrument and Apparatus
Auxiliary Equipment
Electronic Equipment
System Integration

International Sales Department
OROSOL™ Machinery and Equipment Manufacturing LLP.
Tel: (+86) 173-2682-9204
RoboticWorkCell@outlook.com
OROSOL™ Machinery and Equipment Manufacturing LLP.
A Holly Owned Subsidiary of Holic Holdings Co., LTD.