General View of OROSOL® Manufacturer No.8201:
OROSOL Machinery and Equipment Manufacturing LLP is located in China. With Manufacturer No.8201 a National High-Tech Enterprise and has been recognized as an Intellectual Property Protection Key Enterprise and a Unicorn Seed Enterprise. The company specializes in the research, development, and manufacturing of medical electrosurgical energy platforms, plasma surgical equipment, and endoscopic systems. The company has been ranked 7th in the 2025 China Medical Device R&D Strength Ranking and 22nd in the comprehensive ranking, reflecting its strong innovation capabilities. The company has obtained nearly 200 domestic and international patents and has received the National Technology Invention Second Prize, among other honors. Its products have been widely adopted in hospitals across China.

| Product Name & Model | Parameters & Specifications | Features & Applications | ||
|---|---|---|---|---|
| OS-Plasma Bipolar Resection System SM10 | 1. A medical device registration is held for this product. 2. Composition: plasma power source, dual-pedal foot switch, adapter cable and dedicated bipolar electrodes. 3. Rated output frequency 375 kHz. 4. Cutting modes S3, S2, S1, L2 and L1; maximum cutting output 200 W at a rated load of 150 ohm. 5. Coagulation mode DES; maximum coagulation output 120 W at a rated load of 100 ohm. 6. Working medium: normal saline, so the patient does not need a return electrode pad. 7. Electrode design: true bipolar with positive and negative poles on the electrode head, so current returns within the head and does not pass through the sheath or the working handle. 8. Intended use: endoscopic cutting and coagulation of tissue. 9. Application: transurethral resection of the prostate and bladder tumour, and transcervical resection of myoma and cyst. 10. Compatible electrodes: loop, rod, plough and needle configurations in standard and non-standard sizes. 11. Product standard YZB national 7648-2013 plasma bipolar resection and coagulation system. |
1. Performs transurethral plasma resection of the prostate and bladder tumour in a saline medium. 2. Saline irrigation avoids the dilutional hyponatraemia risk associated with hypotonic glycine irrigation. 3. True bipolar current path means no return pad and no current through the sheath in contact with the urethra. 4. Lower thermal spread than monopolar resection shortens catheter time and hospital stay. 5. Five cutting power settings let the surgeon match the output to prostate volume and tissue density. 6. Coagulation mode controls bleeding from the resection bed with a defined power ceiling. 7. Used in urology for benign prostatic hyperplasia and bladder tumour, and in gynaecology for intrauterine lesions. 8. The same power source drives both urological and gynaecological electrodes. 9. A medical device registration is held for this product. |
||
| OS-Plasma Surgery System SM50 | 1. A medical device registration is held for this product. 2. Composition: main unit, dual-pedal foot switch and power cord. 3. Working medium: normal saline. 4. Intended use: with the matching plasma surgical electrodes, cutting and coagulation of uterine cavity, bladder and prostate tissue. 5. Energy delivery: plasma formation at the electrode in a conductive saline field. 6. Electrode interface: accepts the SM1800 series plasma surgical electrodes and the dedicated resection electrode range. 7. Foot switch control with separate cut and coag pedals. 8. Console displays the selected mode and output setting. 9. Application setting: gynaecology hysteroscopic resection and urology transurethral resection. 10. A medical device registration is held for this product. |
1. Drives hysteroscopic resection of myoma, polyp and septum in saline. 2. Drives transurethral resection and vaporisation of the prostate and bladder tumour. 3. One console serves both the gynaecology and urology operating lists. 4. Saline medium removes the risk of a hypotonic irrigation fluid absorbing into the circulation. 5. Bipolar electrode design keeps the current path local to the electrode head. 6. Dual-pedal foot switch leaves both hands free for the resectoscope and the scope. 7. Works with the SM1800 electrode series registered for uterine, prostate and bladder tissue. 8. Used in hysteroscopy suites, urology theatres and day surgery units. 9. A medical device registration is held for this product. |
||
| OS-Plasma Surgery System SM20C | 1. Version: gold edition enhanced model, a higher cutting efficiency variant of the SM20. 2. Modes: SM for cutting and coagulation in normal saline, and VP for coagulation under laparoscopy. 3. Electrode compatibility: accepts the wide coarse resection electrodes specific to plasma resection, which cut more smoothly than standard electrodes. 4. Self-test: automatic electrode recognition at start-up with automatic setting of the matching output power. 5. Coagulation feedback: tissue impedance feedback announced by a distinct audible tone, so the effect is monitored by ear. 6. Safety: saline working medium, no return electrode pad on the patient. 7. Bipolar electrode design with both poles at the head, so current does not reach the sheath or the handle. 8. Thermal spread lower than monopolar resection, with faster post-operative recovery. 9. Application: urological resection of benign prostatic hyperplasia and bladder tumour, gynaecological resection of myoma and cyst. |
1. Provides higher cutting efficiency for large prostates and dense myomas. 2. Wide coarse electrodes remove tissue faster and shorten the resection phase. 3. Automatic electrode recognition removes the risk of selecting the wrong power for the mounted electrode. 4. Audible impedance feedback lets the surgeon judge the coagulation endpoint without looking away from the field. 5. VP mode extends the console to laparoscopic coagulation work. 6. No return pad and no current through the sheath reduce the risk of urethral stricture and contact burns. 7. Saline irrigation removes the risk of absorption of hypotonic fluid. 8. Lower thermal injury shortens recovery and catheterisation time. 9. Used for benign prostatic hyperplasia, bladder tumour, submucous myoma and endometrial polyps. 10. Same console covers urology and gynaecology lists. |
||
| OS-Plasma Surgery System SM20 | 1. Version: gold edition standard model with SM and VP modes. 2. Modes: SM for cutting and coagulation in normal saline; VP for coagulation under laparoscopy. 3. Electrode compatibility: accepts a broad range of dedicated electrodes including coarse and wide resection electrodes. 4. Electrode compatibility: accepts. 5. Saline working medium with no return electrode pad on the patient. 6. Bipolar electrode design with the current loop confined to the electrode head. 7. Self-test with automatic electrode identification and automatic output setting. 8. Coagulation impedance feedback with audible tone change. 9. Application: urological resection of prostate and bladder lesion, gynaecological resection of myoma and cyst. 10. Lower thermal spread than monopolar resection. 11. Standard version of the platform, with the enhanced SM20C available for higher cutting demand. |
1. Covers routine transurethral prostate and bladder resection in saline. 2. Covers hysteroscopic myoma and polyp resection with the same console. 3. Broad electrode compatibility lets one console serve several procedures. 4. No return pad simplifies patient preparation and removes a pad-related burn risk. 5. Current confined to the electrode head protects the urethra and the cervical canal from stray current. 6. Lower thermal injury reduces post-operative dysuria and discharge. 7. Automatic electrode recognition reduces setting errors between cases. 8. Used in urology theatres, hysteroscopy suites and day surgery. 9. Upgrade path to the SM20C or SM50 when the case mix requires more cutting power. |
||
| OS-Plasma Surgical Electrode SM1800 Series | 1. A medical device registration is held for this product. 2. Model range SM1800 through SM1820, twenty-one models. 3. Composition: electrode tip, electrode shaft, connector, handle and cable. 4. Intended use: with the plasma surgery system and the resection endoscope, in normal saline, for transcervical cutting and coagulation of intrauterine tissue and transurethral cutting and coagulation of prostate and bladder tissue. 5. Tip geometries covering loop, rod, plough, needle and button configurations. 6. Shaft lengths 279 mm, 330 mm and 570 mm plus or minus 1 mm for rod and needle types. 7. Standard loop electrode head diameter 6.5 mm plus or minus 0.5 mm with wire diameter 0.35 mm plus or minus 0.1 mm. 8. Plough electrode head diameter 6.5 mm plus or minus 0.5 mm with wire diameter 0.8 mm plus or minus 0.1 mm, curved to follow the enucleation plane. 9. Non-standard loop electrode with head diameter 5.5 mm plus or minus 0.1 mm and wire diameter 0.50 mm plus or minus 0.1 mm, passing a 19 Fr inner sheath for urethral stricture cases. 10. Plough electrode combines enucleation, coagulation, vaporisation and cutting in one tip. 11. Sterilisation: ethylene oxide, single use. 12. A medical device registration is held for this product. |
1. Provides the cutting and coagulation tip for every step of a plasma resection from incision to haemostasis. 2. Loop electrode removes chips of tissue for histology, which a vaporisation electrode cannot provide. 3. Plough electrode follows the enucleation plane for anatomical enucleation of the prostate. 4. Needle and rod electrodes incise and create the marking grooves that guide the resection. 5. Three shaft lengths reach the prostate, the bladder and the uterine cavity through different resectoscope lengths. 6. Small 5.5 mm loop passes a 19 Fr sheath for patients with urethral stricture. 7. Defined wire diameters give a predictable cutting width and coagulation zone. 8. Single-use ethylene oxide sterilised electrode removes reprocessing and keeps the tip sharp. 9. Model range covers urology and gynaecology from one registration on record. |
||
| OS-Resectoscope 26Fr Plasma Set | 1. System designation SM 26Fr, 24Fr and 260 high-energy plasma endoscopic system. 2. Sheath sizes: 26 Fr outer and 24 Fr inner sheath, with a 260 mm working length. 3. Electrode power settings in clinical use: loop electrode cutting 160 W with coagulation 100 W; button electrode vaporisation 50 W with coagulation 30 W. 4. Irrigation: continuous flow with a suprapubic trocar maintaining low pressure at 30 to 50 cmH2O. 5. Optical system: rigid endoscope with an angled direction of view for resection under direct vision. 6. Working element: spring-loaded or rack-and-pinion movement carrying the electrode through the sheath. 7. Inner sheath accepts the loop, button, plough and needle electrodes of the SM1800 series. 8. Outer sheath with a rotating collar to orient the electrode window. 9. Compatible with the SM10, SM20, SM20C and SM50 plasma consoles. |
1. Provides the endoscopic working channel for transurethral resection of the prostate and bladder tumour. 2. Continuous flow irrigation with a suprapubic trocar keeps intravesical pressure low during a long resection. 3. Low irrigation pressure reduces fluid absorption and the risk of a dilutional effect. 4. 26 Fr outer sheath admits a large electrode for rapid removal of a large adenoma. 5. 24 Fr inner sheath is the working channel for the electrode and the optics. 6. Rotating collar lets the surgeon orient the cutting window without turning the whole instrument. 7. Loop electrode at 160 W cuts efficient chips while coagulation at 100 W controls bleeding. 8. Button electrode at 50 W vaporises tissue with a shallow coagulation zone. 9. Used for benign prostatic hyperplasia, bladder tumour and urethral stricture. 10. Same sheath set also used for hysteroscopic resection with the gynaecological electrodes. |
||
| OS-Hysteroscope Modular SMGA | 1. Model range SMGAA, SMGAB, SMGBA and SMGBB, a modular hysteroscope design. 2. Modular construction: outer sheath, operating element and endoscope are separable and sterilised separately. 3. Sterilisation: low-temperature plasma sterilisation suitable for the separated components. 4. Optics: rigid endoscope with an angled direction of view for intrauterine work. 5. Working channel through the operating element for electrodes, scissors and graspers. 6. Continuous flow sheath for distension and clearance of the view. 7. Compatible electrodes: the SM1800 series bipolar plasma electrodes for cutting and coagulation. 8. Compatible consoles: SM50, SM20C and SM20 plasma surgery systems. |
1. Provides hysteroscopic access for resection of myoma, polyp, septum and intrauterine adhesions. 2. Separable sheath, element and scope allow each part to be cleaned and sterilised properly. 3. Low-temperature plasma sterilisation suits the materials and keeps the optics clear. 4. Continuous flow keeps the cavity distended and the view free of blood and debris. 5. Working channel accepts electrodes as well as mechanical instruments for cold cutting. 6. Modular design means a damaged sheath can be replaced without discarding the optics. 7. Used in hysteroscopy suites, day surgery and infertility clinics. 8. Works with the same plasma console used for urological resection. 9. Rigid optics give a stable, high-contrast image during precise intrauterine work. |
||
| OS-Hysteroscope Continuous Flow SMGCC | 1. Models SMGCC with a 5 Fr instrument channel and SMGCD with a 7 Fr instrument channel. 2. Design: one-piece continuous flow hysteroscope with an integrated sheath and optics. 3. Channel sizes 5 Fr and 7 Fr admit scissors, graspers, biopsy forceps and bipolar electrodes. 4. Continuous flow irrigation and suction through separate channels keeps the cavity distended. 5. Rigid endoscope with an angled direction of view. 6. Outer diameter sized for office hysteroscopy and for operating theatre use. 7. Compatible electrodes: the SM1800 series and the dedicated intrauterine electrodes. 8. Sterilisation by low-temperature plasma or per the instructions for use. |
1. Provides diagnostic and operative hysteroscopy through a single integrated instrument. 2. 5 Fr channel suits office polypectomy and targeted biopsy without anaesthesia. 3. 7 Fr channel admits larger graspers and electrodes for myoma and septum resection. 4. Continuous flow keeps the view clear during bleeding, which is the main limitation of a simple diagnostic scope. 5. One-piece design reduces setup time and the number of parts to reprocess. 6. Used for abnormal uterine bleeding, infertility workup, retained products and adhesion division. 7. Works with the plasma console for bipolar cutting and coagulation in saline. 8. Rigid optics give a stable image for precise intrauterine surgery. 9. Fits both the office and the theatre workflow. |
||
| OS-Hysteroscope Straight Channel SMGCA | 1. Models SMGCA and SMGCB with a straight-in instrument channel. 2. Channel geometry: instruments enter straight along the axis of the scope rather than at an angle. 3. Compatibility: accepts shaver blades, rigid cold instruments up to 4 mm diameter, and bipolar electrodes for haemostasis. 4. Advantage of straight entry: the instrument tip stays in the field of view along its whole length. 5. Continuous flow irrigation for distension and clearance. 6. Rigid endoscope with an angled direction of view. 7. Sterilisation per the instructions for use, with low-temperature plasma accepted. 8. Compatible consoles: SM50 and SM20C plasma surgery systems. |
1. Allows mechanical cold cutting with a shaver blade inside the uterine cavity. 2. Straight channel keeps the whole instrument visible, which matters when cutting near the fundus or a cornual recess. 3. Cold blade removal of a myoma avoids thermal damage to the endometrium in a fertility-sparing procedure. 4. Accepts rigid cold instruments up to 4 mm for scissors, graspers and biopsy. 5. Bipolar electrodes can be introduced through the same channel for haemostasis after cold cutting. 6. Combines mechanical and energy-based resection in one scope. 7. Used for myomectomy, polyp resection, septum division and adhesion release in fertility surgery. 8. Works with the shaver system and the plasma console already in the theatre. 9. Continuous flow keeps the view clear during bleeding. |
||
| OS-Disposable Digital Hysteroscopy Catheter SSG811 | 1. Models SSG811 and SSG812, single-use electronic hysteroscopy imaging catheters. 2. Imaging: digital sensor at the distal tip with the image displayed on a monitor. 3. Image processing: AI-based automatic correction that keeps the horizon level when the scope body is rotated. 4. Catheter form: flexible, small-diameter, inserted through the cervical canal. 5. Single use, sterile, supplied ready for the procedure. 6. Workflow: part of the electronic hysteroscopy diagnostic and treatment collaboration system. 7. Compatible console: the SM50 plasma surgery system in the same system configuration. 8. Output: digital image for documentation and review. |
1. Provides office hysteroscopy without a rigid scope, anaesthesia or a theatre slot. 2. AI horizon correction means the image stays upright however the operator rotates the catheter, which shortens the learning curve. 3. Small flexible catheter passes the cervical canal with less discomfort than a rigid hysteroscope. 4. Single-use catheter removes reprocessing and the risk of cross-infection between patients. 5. Digital image capture supports documentation, second opinion and patient counselling. 6. Used for abnormal uterine bleeding, post-menopausal bleeding, infertility workup and endometrial assessment. 7. Fits an outpatient clinic room rather than an operating theatre. 8. Pairs with the plasma console when a lesion found at diagnosis needs immediate treatment. 9. Reduces the capital cost of setting up a hysteroscopy service. |
||
| OS-Plasma Endoscopy Portfolio | 1. Consoles: plasma bipolar resection system SM10, plasma surgery system SM50, SM20C gold edition enhanced and SM20 gold edition, plus the SM10C standard multi-function version. 2. Energy specification of the SM10 platform: 375 kHz output, cutting 200 W at 150 ohm, coagulation 120 W at 100 ohm, cut modes S3, S2, S1, L2, L1 and coag mode DES. 3. A medical device registration is held for this product. 4. Resectoscope: SM 26 Fr, 24 Fr and 260 high-energy plasma endoscopic set with continuous flow sheath and suprapubic trocar irrigation. 5. Hysteroscopes: modular SMGAA, SMGAB, SMGBA and SMGBB; continuous flow SMGCC with 5 Fr channel and SMGCD with 7 Fr channel; straight channel SMGCA and SMGCB accepting shaver blades and rigid cold instruments up to 4 mm. 6. Digital diagnosis: single-use electronic hysteroscopy imaging catheters SSG811 and SSG812 with AI horizon correction. 7. Clinical focus: urology and gynaecology plasma resection under saline, with a shared console and a shared electrode family. 8. Electrodes: SM1800 to SM1820 plasma surgical electrodes under national medical device registration on record, plus loop, plough and needle bipolar resection electrodes. 9. Registrations: national medical device registrations. |
1. Equips a urology and gynaecology day surgery unit with one energy platform and one electrode family. 2. Saline-medium bipolar resection is the core safety argument: no return pad and no hypotonic irrigation fluid. 3. Electrode range covers incision, chip resection, enucleation, vaporisation and haemostasis. 4. Resectoscope and hysteroscope share the same console, so a hospital buys energy capacity once. 5. A medical device registration is held for this product. 6. Digital single-use hysteroscopy catheter extends the service into the outpatient clinic. 7. Cold-cutting channel option supports fertility-sparing myomectomy without thermal injury. 8. Single-use electrodes and catheters remove reprocessing from the workflow. 9. Local research and production in Zhuhai supports service response and custom electrode development. 10. Used in urology, gynaecology, day surgery and outpatient hysteroscopy clinics. |
||
| 8 | Energy Platforms – Electrosurgical Systems | OS-SM-90 Smart Electrosurgical Energy Platform (SM-90) | Type: Integrated electrosurgical energy platform; Model: SM-90; Intended use: laparoscopic and open surgery across multiple departments; Supports plasma bipolar resection under physiological saline irrigation for urology and gynecology; Platform architecture combines multiple energy modes on one generator. | Suitable for laparoscopic and open procedures in multiple surgical departments. Performs plasma bipolar electrosurgical resection in saline environment for urology and gynecology. Serves as the flagship generator of the SM series product line. |
| 9 | Energy Platforms – Electrosurgical Systems | OS-SM-40 Plasma Bipolar Resection & Coagulation System (SM40) | Type: Plasma bipolar electrosurgical generator; Model: SM40; Intended use: endoscopic tissue resection and coagulation; Functions: low-temperature cutting, ablation and hemostasis; Connects multiple dedicated electrodes for different procedures. | Provides low-temperature cutting, ablation and hemostasis in one generator. Accepts a variety of electrodes to support different surgical operations. Extends the saline-based plasma platform to additional departments. |
| 10 | Energy Platforms – Electrosurgical Systems | OS-SM-40C Low-Temperature Plasma Intelligent Surgical System (SM40C) | Type: Intelligent low-temperature plasma surgical system; Model: SM40C; Intended use: controlled real-time low-temperature cutting, ablation and coagulation of soft tissue; Adopts constant-power macro-pulse technology and variable pulse duty cycle; Host self-check and intelligent accessory recognition at start-up; Automatic stop and over-current alarm on abnormal current or short circuit. | Constant-power macro-pulse output with variable duty cycle enables low-damage rapid cutting. Covers hemostasis across different tissue types. Intelligent stability control improves cutting precision and reduces patient trauma. Diversified multi-function electrodes shorten operation time. Built-in safety monitoring halts output and alarms on over-current conditions. |
| 11 | Energy Platforms – Electrosurgical Systems | OS-SM-20 Gold Edition Plasma Generator (SM20) | Type: Plasma bipolar electrosurgical generator; Model: SM20 Gold Edition; Intended use: urological and gynecological endoscopic surgery; Connects multiple special dedicated electrodes; Works with physiological saline as working medium. | Connects various special dedicated electrodes for different procedures. Covers a wide range of urological and gynecological operations. Gold edition configuration of the SM platform series. |
| 12 | Energy Platforms – Electrosurgical Systems | OS-SM-30 Plasma Rehn Knife (SM30) | Type: Plasma surgical knife generator; Model: SM30; Intended use: laparoscopic and open surgery in urology, gynecology, general surgery and thoracic surgery; Functions: cutting, separation and coagulation. | Applicable to laparoscopic and open procedures in urology, gynecology, general surgery and thoracic surgery. Integrates cutting, dissection and coagulation functions. |
| 13 | Gynecology – Hysteroscopes | OS-HYS-A Modular Hysteroscope (SMGAA/SMGAB/SMGBA/SMGBB) | Type: Modular split-type hysteroscope set; Models: SMGAA, SMGAB, SMGBA, SMGBB; Intended use: hysteroscopic diagnosis and operative procedures; Construction: outer sheath, operating element and endoscope fully detachable; Disinfection: components sterilized separately by low-temperature plasma process. | Outer sheath, operating element and telescope separate for independent low-temperature plasma disinfection and sterilization. Modular structure simplifies reprocessing workflow between cases. Covers both diagnostic and operative hysteroscopy. |
| 14 | Gynecology – Hysteroscopes | OS-HYS-B Integrated Hysteroscope with Instrument Channel (SMGCC/SMGCD) | Type: Integrated hysteroscope with built-in working channel; Models: SMGCC with 5Fr instrument channel, SMGCD with 7Fr instrument channel; Intended use: office and operative hysteroscopy. | The SMGCC version carries a 5Fr instrument channel for miniaturized instruments. The SMGCD version carries a 7Fr instrument channel for larger operative tools. Integrated design streamlines setup for office hysteroscopy. |
| 15 | Gynecology – Hysteroscopes | OS-HYS-C Integrated Hysteroscope with Straight-In Channel (SMGCA/SMGCB) | Type: Integrated hysteroscope with horizontal straight-in instrument channel; Models: SMGCA, SMGCB; Intended use: operative hysteroscopy with mechanical and electrosurgical accessories; Channel accepts shaver blade tips, rigid cold-knife instruments up to 4 mm diameter and coagulation electrodes. | The horizontal straight-in channel supports insertion of shaver tips for tissue removal. Accommodates rigid cold-knife instruments with diameter up to 4 mm. Accepts electrodes for intrauterine hemostasis. |
| 16 | Gynecology – Disposable Imaging Catheters | OS-SSG-811 Single-Use Electronic Hysteroscopy Imaging Catheter (SSG811/SSG812) | Type: Single-use electronic hysteroscopy imaging catheter; Models: SSG811, SSG812; Intended use: digital imaging of the uterine cavity; Key technology: AI intelligent image correction during scope rotation. | AI-based correction keeps the image level while the scope rotates. Single-use design eliminates cross-contamination between patients. Provides electronic imaging for hysteroscopic examination. |
| 17 | Gynecology – Integrated Solutions | OS-HYS-SYS Electronic Hysteroscopy Diagnosis & Treatment Collaboration System | Type: Electronic hysteroscopy diagnosis and treatment collaboration system; Intended use: coordinated hysteroscopic diagnosis and treatment workflow. | System-level offering for electronic hysteroscopy diagnosis and treatment collaboration. Listed as an independent product line in the official product catalog. |
| 18 | Urology – Flexible Ureteroscopes | OS-SSJ-801 Electronic Flexible Ureteroscope System (SSJ801/SSJ802) | Type: Electronic flexible ureteroscope system; Models: SSJ801, SSJ802; Intended use: ureteral and renal pelvic endoscopic procedures; Key technology: real-time temperature measurement and temperature control. | Real-time temperature measurement and control enhance procedural safety. Flexible digital access reaches upper urinary tract positions. Two system configurations cover different clinical setups. |
| 19 | Urology – Disposable Endoscopes | OS-SSJ-D Single-Use Electronic Flexible Ureteroscope System | Type: Single-use electronic flexible ureteroscope system; Intended use: single-patient ureteroscopic procedures. | Single-use architecture removes reprocessing burden and cross-infection risk. Complements the reusable SSJ801/SSJ802 platform. |
| 20 | Endoscopic Imaging Systems | OS-CAM-6990 Endoscope Camera System (SC-6990) | Type: Ultra-high-definition endoscope camera system; Model: SC-6990; Image sensor: CMOS; Scanning: progressive scan; Output resolutions: 3840(H)X2160(V) and 1920(H)X1080(V). | Ultra-high-definition imaging supports 4K output at 3840X2160. Switchable 1920X1080 output matches existing display chains. Progressive-scan CMOS sensor delivers low-latency surgical images. |
| 21 | Endoscopic Imaging Systems | OS-CAM-6689 Endoscope Camera System (SC-6689) | Type: Ultra-high-definition endoscope camera system; Model: SC-6689; Image sensor: CMOS; Scanning: progressive scan; Output resolutions: 3840(H)X2160(V) and 1920(H)X1080(V). | Ultra-high-definition CMOS camera head for endoscopic surgery. Dual output resolutions of 3840X2160 and 1920X1080. Progressive scanning ensures smooth live imaging. |
| 22 | Endoscopic Imaging Systems | OS-CAM-6181 Endoscope Camera System (SC-6181) | Type: Full-high-definition endoscope camera system; Model: SC-6181; Image sensor: CMOS; Scanning: progressive scan; Output resolution: 1920(H)X1080(V). | Full-HD 1920X1080 progressive-scan imaging. CMOS sensor platform for standard endoscopy suites. Cost-efficient camera option within the SC series. |
| 23 | Endoscopy Accessories | OS-LS-400 Endoscope Cold Light Source (SL-400) | Type: Medical endoscope cold light source; Model: SL-400; Intended use: illumination for endoscopic surgery, especially laparoscopy; Performance highlights: ultra-quiet operation and excellent heat dissipation. | Ultra-quiet running keeps the operating room noise level low. Excellent heat dissipation supports long procedures. Suited to all endoscopic surgery types, in particular laparoscopic operations. |
| 24 | Surgical Display Systems | OS-DIS-100 Surgical Display Series (SM2360/SM2700/SM8550/SM8320) | Type: Surgical display series for operating rooms; Models: SM2360, SM2700, SM8550, SM8320; Intended use: intraoperative image display for endoscopic surgery. | Multiple display models are available to match different surgical viewing needs. Pairs with the SC series camera systems for complete imaging chains. |
| 25 | Laparoscopy Equipment | OS-INS-100 Multifunctional Insufflator | Type: Multifunctional laparoscopic insufflator; Intended use: pneumoperitoneum maintenance for laparoscopic surgery; Key functions: intelligent insufflation control and circulating smoke evacuation. | Intelligent pneumoperitoneum management stabilizes the working space. Circulating smoke evacuation keeps the surgical field clear and improves safety. |
| 26 | Endoscopy Accessories | OS-IRG-100 Endoscopic Irrigation System | Type: Endoscopic irrigation and suction system; Modes: continuous perfusion without pressure sensing and intelligent perfusion with pressure-sensing automatic speed regulation; Sensing: intelligent dual pressure sensors; Control: microcomputer chip with parameter memory at power-on; Surgical modes: irrigation, percutaneous nephrolithotomy, hysteroscopy and ureteroscopy; Adjustable negative-pressure value and suction flow rate. | Dual perfusion modes let surgeons choose between simple continuous flow and pressure-adaptive intelligent flow. Dual pressure sensors automatically raise pump speed when pressure drops and slow down or stop when pressure peaks, protecting cavity organs and tubing joints. Parameter memory recalls the last settings at start-up and avoids repeated adjustment. Dedicated modes fit percutaneous nephrolithotomy, hysteroscopic resection, ureteroscopic procedures and laparoscopic irrigation-suction. Wide-range adjustment of suction pressure and flow optimizes visualization. |
| 27 | Endoscopy Accessories | OS-FLC-100 Fluid Controller | Type: Working-medium synchronized fluid controller; Intended use: saline drip control synchronized with the electrosurgical generator. | The synchronized working-medium controller operates in step with the host generator. Regulates physiological saline irrigation during plasma procedures. |
| 28 | ENT – Plasma Electrodes | OS-MYE-2011 Plasma Myringotomy Electrode (SM2011 Adult / SM2110 Pediatric) | Type: Plasma myringotomy electrode; Models: SM2011 adult version and SM2110 pediatric version; Intended use: myringotomy or short-term ventilation tube insertion of about three months for secretory otitis media. | Dedicated adult and pediatric electrode sizes are provided. The safe and efficient technique fits day-surgery and primary-care settings for secretory otitis media. |
| 29 | ENT – Plasma Electrodes | OS-ABL-100 Single-Use Plasma Ablation Surgical Electrodes (ENT) | Type: Single-use plasma ablation surgical electrodes; Configuration: multiple electrode models for different ENT procedures; Applications: tonsil and adenoid surgery with excision and hemostasis; Nasal version with suction function protects nasal mucosa during epistaxis control; Laryngeal and tracheal version with built-in saline drip and suction for localized ablation and hemostasis; Also applied to pharyngeal lymphatic follicle and tongue-base tonsil ablation. | The multi-model set easily covers various ENT operations. Supports tonsil and adenoidectomy with hemostasis in one electrode. The suction-equipped nasal electrode stops bleeding while shielding the mucosa. Larynx and trachea electrodes combine ablation, hemostasis, saline drip and suction. Suits precise ablation of pharyngeal lymphatic follicles and tongue-base tonsillar tissue. |
| 30 | Electrosurgical Accessories | OS-BIP-100 Dedicated Bipolar Electrodes | Type: Dedicated bipolar electrodes; Configuration: multiple models; Intended use: endoscopic tissue cutting and coagulation across departments plus open surgery. | Multiple bipolar electrode models serve different departments. Applicable to endoscopic tissue cutting and coagulation and to open procedures. |
| 31 | General Surgery Instruments | OS-GKD-100 Multifunctional Resection & Coagulation Knife | Type: Multifunctional electrosurgical resection and coagulation knife; Functions: tissue grasping, 7 mm vessel sealing, cutting and coagulation in one instrument; Cutting mode: electrosurgical cutting performed via coagulation mode with automatic bipolar coagulation-to-cut transition; Operation: finger-controlled handle trigger. | One instrument completes grasping, 7 mm vessel sealing, cutting and coagulation without instrument exchange. Raises operative efficiency and lowers procedure cost. The ergonomic handle design eases surgeon operation. Automatic coagulation-to-cut transition delivers consistently sharp incisions with reduced thermal damage and bleeding. |
| 32 | Hospital Equipment | OS-TRO-100 Medical Endoscopy Trolley | Type: Medical equipment trolley for endoscopy towers; Structure: all-metal frame with four shelves, four boards and an accessory drawer; Design: integrated modular construction with high-strength load-bearing material; Cable management: hidden internal cable routing; Display: multi-direction adjustable monitor bracket; Casters: four 5-inch silent universal casters with front-wheel brakes. | Holds multiple devices on four shelves with space for camera, scope and light-cable racks. The adapter fixing box keeps the working surface tidy. Hidden cable storage keeps wiring organized. Heavy-load casters with front brakes secure the tower in position. |
| 33 | Operating Room Accessories | OS-SMK-100 Surgical Smoke Circulation Evacuation Device | Type: Surgical smoke circulation evacuation device; Intended use: smoke evacuation and circulation in the surgical field. | Listed independently in the official surgical device catalog. Maintains clear visibility by evacuating surgical smoke. |
Certificates of OROSOL® Medical Device Manufacturer 8201: