Medical Device Manufacturer Catalog No.8473

Medical Device Manufacturer Catalog No.8473

OROSOL® can produce medical device-Advanced Medical Imaging Systems including MRI, CT, DR & Ultrasound.

Item Name: OROSOL® Comprehensive Medical Imaging Solutions.

Brand: OROSOL®

OROSOL® can produce all kinds of medical devices.

If you are interested in this product, please feel free to contact us: RoboticWorkCell@outlook.com

Product Description

Medical Device Manufacturer Catalog No.8473

General View of OROSOL® Manufacturer No.8473:

OROSOL Machinery and Equipment Manufacturing LLP is headquartered in China. Manufacturer No.8473 was established in 2005 and is a National High-tech Enterprise. OROSOL has passed ISO 13485 and ISO 9001 quality system certifications, with total investment of 1.2 billion CNY and total registered capital of 588.3265 million CNY. The company holds over 160 invention patents and has a 50,000 m² production base on a 128 mu site. OROSOL is the first Chinese company to break the technology monopoly of superconducting MRI, with the founding team including 50+ overseas and foreign experts, and has completed 24 million USD in B-round financing.

Medical Device Manufacturer Catalog No.8473

Product Name & Model Parameters & Specifications Features & Applications
OS-MR System Superconducting 1.5 Tesla 1. Superconducting magnet at a stated field strength.
2. Stated bore diameter.
3. Stated maximum gradient amplitude and slew rate.
4. Multi channel receive architecture with a stated coil port count.
5. Stated homogeneity volume.
6. Helium boil off specification stated.
7. Integrated worklist and post processing console.
1. Registration: a medical device registration is held for this product.
2. Field strength sets the baseline signal to noise, and everything done later with coil design or sequence timing is an attempt to recover what the field does not provide.
3. Gradient amplitude and slew rate decide how short an echo time and how fast a sequence can be, which is what makes diffusion and dynamic contrast imaging practical.
4. Bore diameter is a patient access question as much as a comfort one, and it determines whether a larger patient can be scanned at all.
5. Used for routine neuro, musculoskeletal and abdominal imaging.
OS-MR System Superconducting 3.0 Tesla 1. Superconducting magnet at a stated higher field strength.
2. Stated bore and homogeneity.
3. High order shim channels.
4. Stated gradient performance.
5. Parallel imaging acceleration factor stated.
6. Radio frequency transmit configuration stated.
7. Stated acoustic noise level.
1. Registration: a medical device registration is held for this product.
2. Higher field improves signal but also increases susceptibility artefact and radio frequency deposition, so the engineering is as much about managing the penalties as about the gain.
3. High order shimming is what keeps a large field of view usable at this strength, especially near the skull base.
4. Transmit configuration decides whether a dielectric shading artefact can be controlled in a large patient.
5. Used for high resolution neuro, vascular and musculoskeletal imaging.
OS-Coil Radio Frequency Dedicated Custom 1. Receive only coil with a stated element count.
2. Stated anatomy specific geometry.
3. Stated fill factor and coverage.
4. Preamplifier per element.
5. Stated signal to noise improvement over a general coil.
6. Connector type stated.
7. Mechanical flexibility and patient comfort features.
1. Registration: a medical device registration is held for this product.
2. A coil that sits close to the anatomy collects more signal than a larger coil covering the same volume, and that is the whole argument for a dedicated design.
3. Element count increases parallel imaging capability but each element adds a channel and a reconstruction burden.
4. Geometry has to follow the anatomy rather than the scanner, which is why a knee coil and a shoulder coil are not interchangeable.
5. Used to improve image quality for a specific anatomical region.
OS-Magnet Superconducting Custom Design 1. Superconducting magnet with a stated field strength and bore.
2. Stated homogeneity over a defined spherical volume.
3. Stated fringe field footprint.
4. Stated cryogen volume and loss rate.
5. Passive and active shielding option.
6. Stated quench protection path.
7. Site requirement documentation supplied.
1. Registration: a medical device registration is held for this product.
2. Fringe field decides the room the magnet needs, and that room is often the reason a site cannot install a scanner rather than the price of the magnet.
3. Homogeneity over a defined volume is the specification that makes spectroscopy and fat quantification possible.
4. Quench protection is a safety system, and the duct it requires is a building decision that cannot be deferred.
5. Used as the field generating subsystem for imaging and for research platforms.
OS-C Arm Mobile Flat Panel 1. Mobile C arm with a flat panel detector.
2. Stated field of view and pixel size.
3. Stated source to image distance.
4. Motorised or manual orbital movement.
5. Pulsed fluoroscopy with a stated frame rate.
6. Last image hold and storage.
7. Stated thermal capacity for a long case.
1. Registration: a medical device registration is held for this product.
2. Flat panel replaces the image intensifier, which removes the geometric distortion that made measurement unreliable and the vignetting that limited the usable field.
3. Thermal capacity is what determines whether the unit can run an interventional case rather than a few exposures.
4. Last image hold reduces dose by removing the need to keep screening to see the anatomy.
5. Used for orthopaedic, urological and interventional procedures in an operating theatre.
OS-DR System Digital Radiography 1. Flat panel detector with a stated pixel pitch.
2. Stated detector active area.
3. Ceiling or floor mounted tube stand.
4. Automatic exposure control.
5. Stated cycle time between exposures.
6. DICOM worklist integration.
7. Image processing presets by body part.
1. Registration: a medical device registration is held for this product.
2. Pixel pitch fixes spatial resolution at purchase and cannot be improved afterwards, which is why it is the first specification to compare.
3. Cycle time decides throughput in a busy outpatient list, and it is often the real constraint rather than image quality.
4. Body part presets are what keep a department’s images consistent when several radiographers use the room.
5. Used for general radiographic examinations.
OS-Ultrasound System General Imaging 1. Stated transducer port count.
2. Stated display size and resolution.
3. Curvilinear, linear and phased array probe support.
4. Colour and power Doppler.
5. Elastography and contrast modes on selected models.
6. Stated frame rate at depth.
7. DICOM and measurement package.
1. Registration: a medical device registration is held for this product.
2. Frame rate at depth is the specification that separates a system that can be used for a moving structure from one that cannot, and marketing material rarely states it.
3. Transducer port count decides how many examinations can be done without changing a probe.
4. Elastography adds a stiffness estimate that is useful only when the acquisition technique is standardised.
5. Used for abdominal, obstetric and small parts imaging.
OS-Mammography System Digital Breast 1. Stated detector pixel size.
2. Stated anode and filter combinations.
3. Automatic exposure control by breast thickness.
4. Compression paddle with a stated force range.
5. Stated grid configuration.
6. Tomosynthesis option.
7. DICOM output with a CAD interface.
1. Registration: a medical device registration is held for this product.
2. Pixel size has to be small enough to resolve microcalcifications, and that requirement drives the detector rather than the generator.
3. Anode and filter selection changes the beam spectrum, which is how dose is reduced for a thin breast without losing contrast.
4. Compression force is a compromise between dose and comfort, and inadequate compression is the commonest cause of a non diagnostic image.
5. Used for breast cancer screening and diagnosis.
OS-Application Suite MR Angiography 1. Non contrast and contrast enhanced sequences.
2. Stated temporal resolution for dynamic studies.
3. Vessel segmentation and maximum intensity projection.
4. Subtraction and bone removal tools.
5. Stated coverage per station.
6. Workflow with automatic bolus detection.
7. Stated post processing output formats.
1. Registration: a medical device registration is held for this product.
2. A non contrast technique removes the need for a venous line and for gadolinium, which is what makes it usable in a patient with impaired renal function.
3. Temporal resolution determines whether a vessel can be separated from a vein in the same acquisition.
4. Bone removal is a post processing convenience that becomes a diagnostic risk if it is trusted without the source images.
5. Used for carotid, renal and peripheral vascular assessment.
OS-Application Suite Diffusion Tensor 1. Multi direction diffusion encoding with a stated direction count.
2. Stated b value options.
3. Fractional anisotropy and mean diffusivity maps.
4. Tractography with a stated tracking algorithm.
5. Distortion correction.
6. Region of interest statistics.
7. Export of maps and tracts.
1. Registration: a medical device registration is held for this product.
2. Direction count sets the angular resolution of the tract reconstruction, and too few directions produces tracts that look plausible but are wrong.
3. Distortion correction matters at higher field, where susceptibility warping would otherwise displace the tracts relative to the anatomical image.
4. Fractional anisotropy is a summary of directionality rather than a measure of tract integrity, and interpreting it as the latter is a common error.
5. Used for white matter assessment before neurosurgery and in demyelinating disease.
OS-Application Suite Whole Spine 1. Multi station acquisition with automatic table movement.
2. Stated number of stations and overlap.
3. Automatic image stitching.
4. Stated total acquisition time.
5. Sagittal and coronal reformats.
6. Stated coil coverage.
7. Worklist driven protocol.
1. Registration: a medical device registration is held for this product.
2. A single examination of the whole spine answers a question that separate regional scans cannot, because the finding is often at the junction between two regions.
3. Stitching quality depends on the overlap and on patient movement, so the acquisition is designed around stillness rather than speed alone.
4. Automatic table movement is what makes the protocol reproducible between technologists.
5. Used for scoliosis assessment and for suspected multifocal spinal disease.
OS-Application Suite Water Fat Quantification 1. Multi echo acquisition for fat and water separation.
2. Stated echo times and spacing.
3. Fat fraction map output.
4. Region of interest measurement.
5. Stated liver and muscle protocols.
6. Report template with reference ranges.
7. Export to a structured record.
1. Registration: a medical device registration is held for this product.
2. A fat fraction measured by imaging replaces a biopsy for the purpose of tracking steatosis, and that is a meaningful change in what a patient has to undergo.
3. Echo spacing has to be chosen so that the signal model stays valid across the range of fat composition.
4. A reference range is what turns a number into an interpretation.
5. Used for liver fat quantification and for muscle composition assessment.

Certificates of OROSOL® Medical Device Manufacturer 8473:

• ISO 13485:2016 Medical Devices Quality Management System

• ISO 9001:2015 Quality Management System

• US FDA 510(k) Clearance

• NMPA Class II & III Medical Device Registration (multiple products)

• GMP Medical Device Production Quality Management Standard

• National High-tech Enterprise

• National Science and Technology Support Program Undertaker

• National High-end Medical Equipment Application Demonstration Project Undertaker

• 160+ National Invention Patents

E-mail us to get a free quote: RoboticWorkCell@outlook.com