Medical Device Manufacturer Catalog No.8265

Medical Device Manufacturer Catalog No.8265

OROSOL® can produce medical device – Breath Test & Diagnostic Solutions.

Item Name: OROSOL® Breath Test & Diagnostic Solutions.

Brand: OROSOL®

OROSOL® can produce all kinds of medical devices.

If you are interested in this product, please feel free to contact us: RoboticWorkCell@outlook.com

Product Description

Medical Device Manufacturer Catalog No.8265

General View of OROSOL® Manufacturer No.8265:

OROSOL Machinery and Equipment Manufacturing LLP is located in China. Founded in 2002, Manufacturer No.8265 is a National High-Tech Enterprise, a National Specialized and Sophisticated “Little Giant” Enterprise, and a wholly-owned subsidiary of Holic Holdings. The company has been rated as an “AAAA-grade Quality Credit Medical Device Manufacturer” by the Provincial Medical Products Administration, with annual revenue reaching RMB 253 million in 2019. The company holds 47 patents and 11 software copyrights.

Medical Device Manufacturer Catalog No.8265

Product Name & Model Parameters & Specifications Features & Applications
OS-Helicobacter Pylori Analyzer YH04 Series Urea Breath Test System 1. A medical device registration is held for this product.
2. Composition is the housing, movement assembly, control circuit, display, printer and breath card.
3. Model differences stated in the registration are YH04D for dual sample detection, YH04E as the extended type, YH04F as the portable type and YH04AS as the automatic sampling type.
4. Instrument background count rate 40 per minute or less, with eight hour stability of 10 percent or less.
5. Detection uses a high sensitivity thin window Geiger-Mueller tube that directly detects the soft beta radiation energy of carbon 14.
6. Sampling device uses a proprietary open window design with a single use card format, described as the dry detection method.
7. Dual channel data acquisition with no quenching correction required.
8. Results reported automatically as disintegrations per minute together with a six level interpretation: negative, indeterminate, positive one plus, positive two plus, positive three plus and positive four plus.
9. Automatic background subtraction and automatic fault diagnosis.
10. Automatic printout through a built in thermal micro printer.
11. USB communication with automatic patient record storage, a large capacity image and text workstation, and connection to the hospital local area network.
12. Intended use is measurement of collected breath samples in the carbon 14 urea breath test for diagnosis of Helicobacter pylori infection.
13. Earlier registration of the same platform was issued as, showing more than a decade of continuous production.
1. Urea breath test instrument that diagnoses Helicobacter pylori infection without endoscopy, which is the main reason patients accept the test.
2. Thin window Geiger-Mueller detection of carbon 14 beta radiation gives a direct physical measurement rather than an indirect chemical read.
3. Single use card sampling with an open window design means the operator never handles liquid scintillation fluid, so the method is safe and generates no radioactive liquid waste.
4. Six level interpretation including indeterminate separates a weak positive from a clear positive, which matters when deciding whether to treat.
5. Automatic background subtraction removes the daily manual calibration step of earlier liquid scintillation counters.
6. Built in thermal printer gives the patient a paper report at the point of testing.
7. USB connection and hospital network access allow results to reach the electronic record and the referring physician.
8. Used for initial and follow up assessment of dyspepsia, peptic ulcer, chronic gastritis with intestinal metaplasia, gastric MALT lymphoma, gastric cancer family history and long term non-steroidal anti-inflammatory drug users.
OS-Portable H Pylori Analyzer YH04F Compact Breath Test Unit 1. A medical device registration is held for this product.
2. Body dimensions 131 millimetres by 130 millimetres by 161 millimetres.
3. Powered directly from the computer USB port with no separate power supply, giving low voltage and low power consumption.
4. One computer can connect from one to six devices simultaneously, which suits multi station physical examination departments.
5. Breath card inserted into the instrument, with results uploaded to the computer client software for processing, display and automatic printing.
6. Chinese language operating interface with large capacity case storage and multiple report templates.
7. Supports hospital system access with data upload and download and barcode scanning.
8. Reports the same six level interpretation as the larger models, from negative through indeterminate to positive four plus.
9. Printing device can be configured independently because the unit relies on the host computer rather than a built in printer.
10. Sampling device is the proprietary single use card with open window design.
11. Uses the same thin window Geiger-Mueller tube as the rest of the YH04 family.
12. Portable model of the carbon 14 urea breath test analyzer under the same a medical device registration on record, designated YH04F.
1. Portable breath test unit for mobile screening, outreach clinics, physical examination teams and small hospitals.
2. 131 by 130 by 161 millimetre body and USB power mean the unit can be carried in a case and run from a laptop in a village clinic.
3. One computer driving up to six units is the decisive feature for a physical examination centre, where several subjects are tested in parallel.
4. Upload to the host computer means results can be merged into a batch report rather than printed one by one.
5. Barcode scanning links the breath card to the subject, which prevents sample mix-up in a high volume screening session.
6. No separate power supply removes the need for multiple sockets at a temporary screening site.
7. Same detection principle and interpretation scale as the bench models, so results are comparable across sites.
8. Supports gastric cancer risk screening programmes in counties where endoscopy capacity is limited.
OS-Carbon 14 Scintillation Counter YH01A YH01AS Automatic Sampler 1. A medical device registration is held for this product.
2. Composition is the sampling mechanism, photomultiplier tube, sample measurement chamber, analysis and measurement circuit, and display and printing device.
3. YH01A uses a drawer type sampling mechanism while YH01AS uses a rotating disc sampling mechanism.
4. Instrument background count rate 70 counts per minute or less.
5. Detection efficiency 85 percent or more.
6. Intended use is measurement of collected breath samples in the carbon 14 urea breath test for diagnosis of Helicobacter pylori infection.
7. Rotating disc automatic sampler version allows sequential processing of a batch of breath samples without manual insertion of each sample.
8. Liquid scintillation counting method, distinguished from the dry card method of the YH04 family.
9. Display and printing device reports the measurement result directly.
1. Liquid scintillation counter for laboratories that prefer the classical carbon 14 measurement method over the dry card approach.
2. Photomultiplier detection with 85 percent efficiency or better gives a high counting yield on low activity breath samples.
3. Background of 70 counts per minute or less is the specification that determines the low end sensitivity of the test.
4. Rotating disc sampler version processes a batch sequentially, which suits a hospital laboratory running a morning breath test list.
5. Drawer sampler version is simpler and cheaper for a clinic that tests a few patients per day.
6. Used in the same clinical indications as the dry card analyzer, namely dyspepsia, peptic ulcer, chronic gastritis and gastric cancer risk assessment.
7. A medical device registration is held for this product.
8. Both sampler formats share the same electronics and software, which simplifies service and spare parts for a hospital running both.
OS-Urea Breath Test Breath Card and Sampling Device Consumable 1. Single use breath card and sampling device consumed by the YH04 series analyzers, supplied under the analyzer registration and listed separately in provincial procurement platforms as the dedicated consumable.
2. Card format sampling device with an open window design protected by proprietary technology, described as the dry detection method.
3. No liquid scintillation fluid is used, so no radioactive liquid waste is generated and the operator is not exposed to liquid radioactive material.
4. Pack format 40 tests per box in the Jiangxi provincial dynamic procurement listing with a published price of 1800 yuan per box.
5. Shandong provincial consumable price listing records the breath card as the dedicated consumable of the YH04 series analyzer at 2120 yuan per box.
6. Card is inserted directly into the analyzer without any reagent addition or extraction step.
7. Sampling procedure requires the patient to exhale into the card after swallowing the carbon 14 urea capsule and waiting 15 minutes.
8. Total diagnostic process from capsule ingestion to result is about 25 minutes.
9. Card is disposed of as ordinary dry waste after reading, which simplifies waste handling compared with liquid scintillation vials.
10. Supplied together with the single direction valve sampling device and the automatic sampling accessory for the automatic sampler model.
11. Pack format 40 tests per box in the provincial dynamic procurement listing with a published price of 1800 yuan per box.
12. Provincial consumable price listing records the breath card as the dedicated consumable of the YH04 series analyzer at 2120 yuan per box.
1. Consumable that makes the dry breath test practical, because it replaces the liquid scintillation cocktail and its radioactive waste stream.
2. Open window card design with a proprietary technology is the technical core of the dry method and the reason the instrument can report a result without quenching correction.
3. Insert and read operation requires no reagent handling, so a nurse or a technician can run the test without a radioisotope laboratory.
4. Published provincial prices give hospital procurement a reference point and make the cost per test predictable.
5. 40 test box matches a week of routine breath testing in a mid-sized hospital gastroenterology department.
6. Dry waste disposal removes the regulatory burden of radioactive liquid waste, which is the main reason many hospitals abandoned liquid scintillation counters.
7. Used with the carbon 14 urea capsule as the complete breath test kit.
8. Recurring card consumption is the economic base of the installed analyzer fleet.
OS-Carbon 13 Breath Analyzer Su pi one Ratio Measurement System 1. A medical device registration is held for this product.
2. Composition is the optical system, sampling system, control system, software release version 1 and optional accessories.
3. Optional accessories are an automatic test tube sampling device and a barcode scanner.
4. Measurement compares the ratio of carbon 13 dioxide to carbon 12 dioxide in the sample breath against the same ratio in the baseline breath, and the difference determines whether the subject is infected with Helicobacter pylori.
5. Non radioactive method using the stable carbon 13 isotope instead of carbon 14.
6. Automatic tube sampling accessory allows a batch of collected tubes to be processed without manual insertion.
7. Barcode scanner links each sample tube to the subject record.
8. Software release version 1 controls measurement, calculation and reporting.
9. A medical device registration is held for this product.
10. Carbon 13 breath analyzer under a medical device registration on record, model Su pi one.
1. Stable isotope breath analyzer that removes radioactivity from the urea breath test entirely, which matters in paediatric use, in pregnancy and in hospitals without a radioisotope licence on record.
2. Carbon 13 is a naturally occurring stable isotope, so no radioactive waste, no radiation protection programme and no special disposal route are needed.
3. Ratio measurement against the baseline sample corrects for the subject’s natural carbon 13 background, which is the key to accuracy.
4. Automatic tube sampling and barcode scanning make the analyzer suitable for a batch screening programme rather than single tests.
5. Newest registration in the portfolio, showing the maker is moving from carbon 14 toward the stable isotope method.
6. Used for the same indications as the carbon 14 systems, including dyspepsia, peptic ulcer, chronic gastritis and gastric cancer family history screening.
7. Suitable for paediatric gastroenterology, where a radioactive test is difficult to justify.
8. Complements rather than replaces the carbon 14 line, because carbon 13 consumables cost more per test.
OS-Carbon 13 Infrared Spectrometer YH08 YH08A Breath Analysis System 1. A medical device registration is held for this product.
2. YH08 composition is the main unit, software, data cable, filter and sampling bag.
3. YH08A is a stand alone version composed of the main unit, filter and sampling bag, without the software and data cable.
4. Measurement analyses the change in carbon 13 abundance of the sample breath over the baseline breath, expressed as the delta over baseline in per mille, to determine whether the patient is infected with Helicobacter pylori.
5. Infrared spectrometric detection of the carbon 13 dioxide absorption signal.
6. Sampling bag collection allows samples to be taken at a remote site and analysed later in the laboratory.
7. Filter protects the optical cell from moisture and particulate contamination.
8. Stand alone YH08A version reports directly without a computer connection.
9. A medical device registration is held for this product.
10. Carbon 13 infrared spectrometer under a medical device registration on record, models YH08 and YH08A, continuing the earlier registration on record.
1. Infrared based carbon 13 breath analyzer for hospitals that want stable isotope testing without the cost of a mass spectrometer.
2. Delta over baseline reporting in per mille is the standard expression used in the carbon 13 urea breath test literature, so results are directly comparable with published cut-offs.
3. Sampling bag collection decouples sampling from analysis, which allows a rural clinic to collect and send samples to a county laboratory.
4. Stand alone YH08A version suits a small hospital that does not want a computer at the testing bench.
5. Filter protection extends optical cell life, which is the main maintenance cost of an infrared breath analyzer.
6. No radioactivity means no licence on record, no shielding and no radioactive waste contract.
7. Used for Helicobacter pylori diagnosis and for treatment follow up after eradication therapy.
8. Third carbon 13 registration in the portfolio alongside the Su pi one analyzer, giving the maker both infrared and ratio measurement options.
OS-Urea Breath Test Clinical Procedure and Safety Management 1. Standard operating procedure defined for the urea breath test using the carbon 14 capsule and breath card of the maker.
2. Patient must fast or take no food for three hours before the test.
3. Capsule must be swallowed whole with warm water and must not be broken in the mouth, because capsule rupture invalidates the result.
4. Patient sits quietly for 15 minutes after swallowing the capsule, then exhales into the breath card.
5. Breath card is inserted into the analyzer and the diagnosis is printed, with the whole process taking about 25 minutes.
6. Antibiotics, bismuth agents and proton pump inhibitors must be stopped for one month before testing because they suppress Helicobacter pylori and cause false negative results.
7. Testing should be deferred for one week after acute upper gastrointestinal bleeding, which also suppresses the organism.
8. Partial gastrectomy may cause rapid emptying of the isotope from the stomach and reduce test accuracy.
9. Indications listed for the test are initial and follow up dyspepsia, peptic ulcer, chronic gastritis with marked abnormality, gastric MALT lymphoma requiring eradication, gastric cancer prevention and family history, patients who refuse endoscopy, and long term non-steroidal anti-inflammatory drug users.
10. A medical device registration is held for this product.
11. Production licence for the site is food and a drug medical device manufacturing licence on record.
1. Procedure and safety framework that determines whether a breath test result can be trusted, independent of the instrument used.
2. One month withdrawal of antibiotics, bismuth and proton pump inhibitors is the single most important pre-analytical condition, and the most common cause of a false negative in practice.
3. Whole capsule swallowing requirement is a simple instruction that prevents a large share of invalid tests.
4. Deferral after acute gastrointestinal bleeding and caution after gastrectomy protect against systematically wrong results in specific patient groups.
5. Indication list matches the clinical guidelines for Helicobacter pylori testing, including the gastric cancer prevention indication that drives most screening volume in China.
6. Non-invasive nature of the test is the reason it is preferred over endoscopy-based testing for follow up after eradication.
7. Manufacturing licence documentation supports hospital source qualification and provincial procurement registration on record.
OS-Portfolio Yanghe Medical Device Urea Breath Test Specialist 1. Established, registered capital 7.75 million yuan, operating as a small central state owned enterprise.
2. Affiliated to China National Nuclear Group with ultimate control by the State-owned Assets Supervision and Administration Commission of the State Council, in a group of 1437 member entities.
3. Intellectual property position of 10 granted proprietary technology, 19 proprietary design, 5 proprietary design and 20 software copyrights.
4. A medical device registration is held for this product.
5. Grade A taxpayer with a portfolio of 26 product and service entries.
6. Product registrations are the YH04 series helicobacter pylori analyzer under, the YH01A and YH01AS carbon 14 scintillation counter under, the Su pi one carbon 13 breath analyzer under and the YH08 and YH08A carbon 13 infrared spectrometer under.
7. Has participated in drafting group standards in the field.
8. Nuclear group affiliation provides access to radioisotope handling competence, which is the technical reason a nuclear industry entity became a breath test specialist.
9. Branch operation includes a drug distribution department established in December 2011.
1. Portfolio summary of a small state owned medical device maker that specialises entirely in Helicobacter pylori breath testing.
2. Nuclear industry parentage explains the original competence in handling carbon 14 and in radiation detection instrumentation.
3. Four registrations across two isotopes and two measurement principles give the widest breath test portfolio of any single Chinese maker.
4. Carbon 14 dry card systems serve the high volume, low cost hospital market while carbon 13 systems serve paediatrics, pregnancy and sites without a radioisotope licence on record.
5. Consumable breath cards listed in provincial procurement platforms create a recurring revenue stream attached to the installed analyzer base.
6. Central state ownership and State-owned Assets Supervision and Administration Commission control support qualification in public hospital tenders.
7. Ten proprietary technology and 20 software copyrights indicate that the open window card design and the automatic sampler are genuinely proprietary.
8. More than twenty years of continuous operation in one product niche is unusual in Chinese in vitro diagnostics, where most makers diversify across many platforms.

Certificates of OROSOL® Medical Device Manufacturer 8265:

  • ISO 13485:2016 — Medical Devices Quality Management System
  • NMPA Medical Device Registration Certificate (Class II) — Multiple registrations for breath test analyzers and consumables
  • NMPA Class I Medical Device Filing — (Single-Use Breath Sampling Device)
  • National High-Tech Enterprise
  • National Specialized and Sophisticated “Little Giant” Enterprise
  • AAAA-grade Quality Credit Medical Device Manufacturer
  • Anhui Provincial Pharmaceutical Quality Award
  • RoHS Compliant — Restriction of Hazardous Substances Directive (EU)
  • REACH Compliant — Registration, Evaluation, Authorization and Restriction of Chemicals (EU)

E-mail us to get a free quote: RoboticWorkCell@outlook.com